Chamber Material:
Optional
Choose Options
SF - 316 Stainless Steel <400˚F (204˚C) (Standard) -Sub-Flange Mount
CF - Hastelloy C-276 < 400˚F (204˚C) -Sub-Flange Mount
TF - 316 Stainless Steel w/TFE Coating < 400˚F (204˚C) -Sub-Flange Mount (no chamber isolation valve option)
NF - 316 Stainless Steel w/ SilcoNert™ 2000 Coating < 400˚F (204˚C) -Sub-Flange Mount
SHF - 316SS Hi Temp w/Kalrez® < 550˚F (288˚C) -Sub-Flange Mount
CHF - Hastelloy C-276 Hi Temp w/Kalrez® < 550˚F (288˚C) -Sub-Flange Mount
NHF - 316 Stainless Steel w/ SilcoNert™ 2000 Coating Hi Temp w/ Kalrez® < 550˚F (288˚C) -Sub-Flange Mount
SFU = 316 Stainless Steel <400˚F (204˚C) (Standard) -Sub-Flange Mount/unheated
CFU - Hastelloy C-276 < 400˚F (204˚C) -Sub-Flange Mount/unheated
TFU - 316 Stainless Steel w/TFE Coating < 400˚F (204˚C) -Sub-Flange Mount (no chamber isolation valve option)/unheated
NFU - 316 Stainless Steel w/ SilcoNert™ 2000 Coating < 400˚F (204˚C) -Sub-Flange Mount/unheated
SHFU - 316SS Hi Temp w/Kalrez® < 550˚F (288˚C) -Sub-Flange Mount/unheated
CHFU - Hastelloy C-276 Hi Temp w/Kalrez® < 550˚F (288˚C) -Sub-Flange Mount/unheated
NHFU - 316 Stainless Steel w/ SilcoNert™ 2000 Coating Hi Temp w/ Kalrez® < 550˚F (288˚C) -Sub-Flange Mount/unheated
SFV = 316 Stainless Steel <400˚F (204˚C) (Standard) -Sub-Flange Mount/heated
CFV - Hastelloy C-276 < 400˚F (204˚C) -Sub-Flange Mount/heated
TFV - 316 Stainless Steel w/TFE Coating < 400˚F (204˚C) -Sub-Flange Mount (no chamber isolation valve option)/heated
NFV - 316 Stainless Steel w/ SilcoNert™ 2000 Coating < 400˚F (204˚C) -Sub-Flange Mount/heated
SHFV - 316SS Hi Temp w/Kalrez® < 550˚F (288˚C) -Sub-Flange Mount/heated
CHFV - Hastelloy C-276 Hi Temp w/Kalrez® < 550˚F (288˚C) -Sub-Flange Mount/heated
NHFV - 316 Stainless Steel w/ SilcoNert™ 2000 Coating Hi Temp w/ Kalrez® < 550˚F (288˚C) -Sub-Flange Mount/heated
Flange Size:
Optional
Choose Options
F1 - 1.5" Flange
F2 - 2" Flange
F3 - 3" Flange
F4 - 4" Flange
F6 - 6" Flange
F1T - 1.5" Flange - Top Dead Center
F2T - 2" Flange - Top Dead Center
F3T - 3" Flange - Top Dead Center
F4T - 4" Flange - Top Dead Center
F6T - 6" Flange - Top Dead Center
Chamber Heat Control:
Optional
Choose Options
340 - 340˚F (171˚C) Temp Switch (Standard) - Mandatory for FM/ ATEX Approved Units (Standard)
375 - 375˚F (190˚C) Temp Switch
550 - 550˚F (288˚C) Temp Switch
R - RTD Only
K - T/C Only, Type K
Blowback Type:
Optional
Choose Options
BB - Blowback
BT - Blowback w/ Smart Timer
HB - Heated Blowback
HT - Heated Blowback w/Smart Timer
N - No Blowback
Blowback Port:
Optional
Choose Options
S - Standard Blowback
P - Blowback Probe Tip Filter Only - No Chamber Blowback
N - No Blowback
Blowback Valve:
Optional
Choose Options
24 - 24 VDC Actuator
1 - 115 VAC Actuator
2 - 230 VAC Actuator
A - Pneumatic Actuator
N - No Blowback
Heat Shrink Boot:
Optional
Choose Options
FG2 - Fiberglass Enclosure, 2" Boot.
FI2 - Fiberglass Enclosure, Insulated, 2" Boot.
SS2 - Stainless Steel Enclosure, 2" Boot.
SI2 - Stainless Steel Enclosure, Insulated, 2" Boot.
FG - Fiberglass Enclosure, 3" Boot
FI - Fiberglass Enclosure, Insulated, 3" Boot
SS - Stainless Steel Enclosure, 3" Boot
SI - Stainless Steel Enclosure, Insulated, 3" Boot
FG4 - Fiberglass Enclosure, 4" Boot
FI4 - Fiberglass Enclosure, Insulated, 4" Boot
SS4 - Stainless Steel Enclosure, 4" Boot
SI4 - Stainless Steel Enclosure, Insulated, 4" Boot
Enclosure Heat Control:
Optional
Choose Options
N - No Enclosure Heat
T - 225˚F (107˚C) Temp Switch
K - T/C Only, Type K
R - RTD Only
Power/Classification:
Optional
Choose Options
1 - 115 VAC General Purpose
2 - 230 VAC General Purpose
1FM - 115 VAC Approved for Class I, DIV. II, Grp. B, C, D (FM/ CSA)
2FM - 230 VAC Approved for Class I, DIV. II, Grp. B, C, D (FM/ CSA)
1EX - 115 VAC ATEX Approved for Zone IIC (TUV)
2EX - 230 VAC ATEX Approved for Zone IIC (TUV)
Filter:
Optional
Choose Options
2 - 2μm Ceramic
1 - 1μm Ceramic
C - 0.1μm Ceramic coated
S - 2 μm Sintered 316SS
Temperature/Alarm:
Optional
Choose Options
F - Failsafe (Open on Alarm)
C - Closed on Alarm
R - 100 Ohm RTD (Includes Failsafe Alarm Contact)
K - Type K Thermocouple (Includes Failsafe Alarm Contact)
N - No Temperature Alarm
Ammonia Converter:
Optional
Choose Options
N -No Ammonia Convertor
A - Integrated on the Right Side of the 270
Extended Length Probe Tube Support:
Optional
Choose Options
N - Standard Probe Tube Support
2C - 2 ft Hast C probe tube support
2S - 2 ft 316SS probe tube support
2T - 2 ft 310SS probe tube support
3C - 3 ft Hast C probe tube support
3S - 3 ft 316SS probe tube support
3T - 3 ft 310SS probe tube support
4C - 4 ft Hast C probe tube support
4S - 4 ft 316SS probe tube support
4T - 4 ft 310SS probe tube support
5C - 5 ft Hast C probe tube support
5S - 5 ft 316SS probe tube support
5T - 5 ft 310SS probe tube support
Heated Probe Adapter:
Optional
Choose Options
N - No HPA
K - Type K T/C Terminal Blocks
R - RTD Terminal Blocks
S - Standalone HPA - No Terminal Blocks
Z-Purge Panel:
Optional
Choose Options
N - No Z-Purge
H - Mounted on Top of 270
V - Mounted on Side of 270